Fluke 1520 megohmmeter
Ohm is a measure of electrical resistance. The amount a material reduces the electric current that runs through it is the amount of electrical resistance. Megohmmeters get their names by measuring large numbers of ohms. Meggers read values out in megohms, where 1 megohm is equal to 1,000,000 ohms.
What resistance range uses a megohmmeter?
A megohmmeter is a high-resistance ohmmeter used to measure insulation deterioration on various wires by measuring high resistance values during high voltage test conditions. Megohmmeter test voltages range from 50 V to 5000 V.
Can megger measure 1000 ohms?
It is also known as mega-ohm-meter. It is used in several areas like multi-meters, transformers, electrical wiring, Etc. Megger device is for testing various electrical devices that can measure greater than 1000 meg-ohms.
How do you use a Fluke megger?
And I'll press the test button and you'll see it applied. In this case 1052 volts and read 10.0 mega
When using a megger you must avoid touching?
Megger Test Safety Precautions Use megger test on high-resistance measurements only, such as insulation measurements or to check two separate conductors on a cable. Never touch the test leads while the handle is being cranked.
What is the difference between a multimeter and a megohmmeter?
The multimeter can be used as an ammeter, an ohm meter, or a voltmeter. Meggers are used to measure insulation resistance.
What are good megohmmeter readings?
Anything reading between 2 megohms and 1000 megohms is usually considered a good reading, unless other problems have been noted. Anything less than 2 megohms indicates an insulation problem.
Is a hipot the same as a megger?
Essentially, both the high-pot and the megohmmeter do the same thing, but with vastly different outcomes. Both instruments apply a comparatively high voltage across insulation and draw leakage current through the insulation, commensurate with its insulating properties and condition.
What does OL mean on a megohmmeter?
If your megohmmeter is reading "OL" (over load) or "I" (infinity), these are commonly used readings on megohmmeters when the measurement exceeds the maximum indicated value of the tester.
What is a good megger reading for a 480V motor?
IEEE recommends that for motor starting that the operational voltage, expressed as a meg-ohm value doubled plus 1000 is the minimum meg value for starting. For a 480V motor that would mean . 480Meg x 2= . 960 Meg + 1000, so a minimum ground resistance for starting a 480V is 1.960 Meg or round up to 2 meg-ohms.
What is acceptable value for megger?
Max.Voltage Rating Of Equipment | Megger Size | Min.IR Value |
---|---|---|
600 Volts | 1,000 Volts | 100 MΩ |
5 KV | 2,500 Volts | 1,000 MΩ |
8 KV | 2,500 Volts | 2,000 MΩ |
15 KV | 2,500 Volts | 5,000 MΩ |
What is the difference between insulation tester and megger?
An insulation tester performs the basic measuring function a megohmmeter does—measuring very high resistance values by sending a high voltage signal into the object being tested—and it often does much more; it usually performs more functions, including more complex testing and recording of measurements.
Can a Megger damage insulation?
Using a megger meter is not destructive. When insulation has been damaged, a megger tester is used in determining the cause by testing. The test is typically conducted at rates that are low as compared to the insulation.
What is the minimum acceptable insulation resistance?
For many years, maintenance professionals have used the one-megohm rule to define the allowable lower limit for insulation resistance. The rule states that insulation resistance should be approximately one megohm for each 1000 volts of operating voltage, with a one megohm minimum.
How do you test wire with a Megger?
So what we're gonna be doing is putting some voltage through the wire. And then. We're gonna put one
Can you shock yourself with a Megger?
The megger supplies over 500 volts, and that is enough to give a fatal shock.
Can an insulation tester shock you?
Insulation testers are limited to no more than a few milli-Amps of test current. If insulation were to pass any more than that, it could no longer be considered insulation. Remember, 5 milli-Amps will shock you, and 50 milli-Amps can kill you.
How many volts does a Megger put out?
The Megger dC dielectric Test Sets are available with voltage outputs ranging from 5 kV up to 160 kV.
Can you use a multimeter to test insulation resistance?
You use your insulation multimeter to check the insulation resistance of each conductor to ground and of each conductor to the other two.
How do you connect a 3 phase motor to a megohmmeter?
- Turn off the power supply to the motor, usually accomplished by switching the circuit breaker.
- Place one megger probe to the any mounting bolt on the breaker box to test for grounding continuity, then touch the other probe to a motor terminal.
- Crank the handle for about a minute, and notice the resistance reading.